Perth Artifactory

Trace:

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
tools:hp3456a_digital_voltmeter [2017/06/25 14:45]
steve created
tools:hp3456a_digital_voltmeter [2020/03/12 12:49] (current)
Line 19: Line 19:
 By default, 5 1/2 digits are shown.  If you want faster readings, this can be reduced to 3 1/2 digits.  For 6 1/2 digits resolution the meter must be set to integrate over a longer period. By default, 5 1/2 digits are shown.  If you want faster readings, this can be reduced to 3 1/2 digits.  For 6 1/2 digits resolution the meter must be set to integrate over a longer period.
  
- 6 1/2 digits: +  * 6 1/2 digits: 
-   - press "1", "0", "0", "STORE", "CHS"+    press "1", "0", "0", "STORE", "CHS"
  
 Note that the CHS button is also labelled "N CYC INT" You have set the integration time to 100 power line cycles, this will enable 6 1/2 digits. Note that the CHS button is also labelled "N CYC INT" You have set the integration time to 100 power line cycles, this will enable 6 1/2 digits.
Line 27: Line 27:
  
 Then: Then:
-  6 digit display: +  6 digit display: 
-    press "6", "STORE", "9"+    press "6", "STORE", "9"
  
 Note that the "9" button is also labelled "N DIG DISP" Note that the "9" button is also labelled "N DIG DISP"