User Tools

Site Tools


tools:benchpsu

DSE 0—30V 2.5A Lab Power Supply

Specifications

  • Output voltage: 0—30 V DC
  • Output current: 2.5A max
  • Load regulation (0-100% load): 10mV
  • Ripple and noise: 5mV RMS
  • Voltmeter accuracy: ±1.0%
  • Ammeter accuracy: ±1.0%
  • Mains overcurrent protection: 1A resettable circuit breaker

Setting up and using

  1. With the power supply still turned off, disconnect any loads from its output terminals
  2. Turn the power supply on and turn the voltage control knob until the left LCD displays the desired voltage
  3. If you do not need to set a specific maximum current, set turn the current control knob to 'high'; if you do, then
    • set the current control knob to just above 'low',
    • short the power supply's output,
    • adjust the current knob until the right LCD displays the desired maximum current, and
    • remove the short
  4. The power supply is now ready to use

Warnings

  • Do not block any of the ventilation holes as this may cause the power supply to overheat
  • Do not use the spring-loaded terminals on the front panel for currents in excess of 1A

Resources and further information

A copy of the power supply's user manual is available here. In the event of a failure, please notify artifactory-core and/or Peter Dreisiger.

DSE 0—30V 5A Lab Power Supply

Specifications

  • Output voltage: 0—30 V DC
  • Output current: 5A max
  • Load regulation (0-100% load): 40mV
  • Ripple and noise: 5mV RMS
  • Voltmeter accuracy: 7% of full-scale deflection
  • Ammeter accuracy: 7% of full-scale deflection
  • Mains overcurrent protection: 2A resettable circuit breaker
  • Cooling system: fan-forced air

Setting up and using

  1. With the power supply still turned off, disconnect any loads from its output terminals
  2. Turn the power supply on and turn the voltage control knob until the left meter displays the desired voltage
  3. If you do not need to set a specific maximum current, set turn the current control knob to 'high'; if you do, then:
    • set the current control knob to just above 'low',
    • short the power supply's output,
    • adjust the current knob until the right meter displays the desired maximum current, and
    • remove the short
  4. The power supply is now ready to use

Warnings

  • Do not block any of the ventilation holes as this may cause the power supply to overheat
  • Do not use the spring-loaded terminals on the front panel for currents in excess of 1A

Resources and further information