projects:statusboard

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
projects:statusboard [2016/08/03 00:12]
elwell created
projects:statusboard [2020/03/12 12:49] (current)
Line 1: Line 1:
-Grand Master plan to replace the ABS box containing doorbot with something larger.+Grand Master plan to replace the [[projects:opendoorcontrol|ABS box containing doorbot]] with something larger.
  
   * Move the PSU / Battery backup higher up the wall   * Move the PSU / Battery backup higher up the wall
   * Make wooden frame (to go over existing burglar alarm panel) to take ply/mdf engraved front   * Make wooden frame (to go over existing burglar alarm panel) to take ply/mdf engraved front
-  *   * Will also need to be clear of lightswitch on side of distribution board +    * Will also need to be clear of lightswitch on side of distribution board 
-    * Needs to be over ribbon cable from external readers/led/button +    * Needs to be over ribbon cable from external readers/led/button 
-    * Needs to be able to pick up cables to door solenoid+    * Needs to be able to pick up cables to door solenoid
   * LCD Display for basic status   * LCD Display for basic status
   * Light switch (momentary push with indicator) for floodlight PSU - see below   * Light switch (momentary push with indicator) for floodlight PSU - see below
   * Simple green / red open/close space buttons that also update spaceapi and coloured sign   * Simple green / red open/close space buttons that also update spaceapi and coloured sign
   * excessive decoration / branding   * excessive decoration / branding
 +  * Connects to external doorbell and RGB LED
  
 Contraints Contraints
Line 22: Line 23:
 Basic idea thrown to the list on https://groups.google.com/forum/#!topic/artifactory-core/a8n6lxrAz54 Basic idea thrown to the list on https://groups.google.com/forum/#!topic/artifactory-core/a8n6lxrAz54
  
-The external floods are being driven off an old HP DPS600PB Server PSU (http://www.rcgroups.com/forums/showthread.php?t=1581061), which not only gives us 12v at 27A (remote start via shorting several pins together) but also 5v at 7A on standby. The latter would be ideal for the _beacon of guthrie st_ (fed via one of the relays) and the main PSU start/stop can be done via the PsON and PsKILL to ground, also via one of the relays.+The external floods are being driven off an old HP DPS600PB Server PSU (http://www.rcgroups.com/forums/showthread.php?t=1581061), which not only gives us 12v at 27A (remote start via shorting several pins together) but also 5v at 7A on standby. The latter would be ideal for the [[projects:lightboxsign|beacon of guthrie st]] (fed via one of the relays) and the main PSU start/stop can be done via the PsON and PsKILL to ground, also via one of the relays.
  
 Additional logic can be added to Doorbot (https://github.com/Perth-Artifactory/doorbot) to turn on the coloured sign on and annouce 'space open' to spaceapi by member hitting the 'open space' button and turning floodlights off (after a delay) if dark and closing space, (perhaps flash sign?) when they hit the 'close space' button. Additional logic can be added to Doorbot (https://github.com/Perth-Artifactory/doorbot) to turn on the coloured sign on and annouce 'space open' to spaceapi by member hitting the 'open space' button and turning floodlights off (after a delay) if dark and closing space, (perhaps flash sign?) when they hit the 'close space' button.
  • projects/statusboard.1470154326.txt.gz
  • Last modified: 2020/03/12 12:49
  • (external edit)